Glass Touch (8 ZONE) Zone Selection and Spill Function


Please read instructions carefully and follow steps!

Note! All used keys must be activated and spill zone selected before installation can proceed to ensure correct functionality.


Step 1. Power up the MCM (main control module) by connecting transformer to 24VAC port. (The minimum of the transformer is 2A, 24VAC)


Step 2. Press (B) and hold until one RED light flashes.


Step 3. You are now going to activate used keys.

Short press (B) followed by short pressing (A) showing a solid RED light then toggle through short pressing (B) and then (A) one at a time until all active keys are selected showing solid RED light. All deactivated keys should show no RED light.

Step 4. You are now going to activate Spill Zone.

Now that you have activated used keys, toggle through keys and short push (B) until you land on the desired key for your spill zone. This will be the only key flashing brightly RED, press (B) and hold until light stops flashing. You will now have a GREEN light alongside your selected spill zone. You have now completed Glass Touch Set UP.

To make changes to all functions hold (B) until one of the RED lights flashes brightly to make any required changes.

Note. The touch pad can be connected to any (RJ45, 8 pin) sockets on the MCM. And it will not affect the selection of the zones.

Step 5. Find a clean dust free environment, remove yellow paper cover and apply selected zone labels squarely in place ensuring you DO NOT TOUCH the sticky clear window with your fingers as this will show marks on the front window

.

 

For further information, please email to info@buffalo.net.au

 

Return to the main list